2. 在串口里面對板子測試模式進(jìn)行如下設(shè)置:
a) Standard Module---a) TX Power Test (CW)---- a) Output ConTInuous—按+
或者-切換通道,直到channel18
3. 頻譜分析儀設(shè)置
Set analyzer to : Center frequency = 2.44 GHz , span = 2 MHz , Ref amp = 0 dBm. 測試截圖
6. 測試結(jié)果計(jì)劃及預(yù)期值
Measured frequency : 2.440 GHz
ppm value = (2440012 - 2440000 ) / 2.440 = 4.9 ppm 《《 25ppm (AddiTIonal
+/-15ppm allowance for temp. & ageing)
7. (測試值-這個通道的中心頻點(diǎn))/這個通道的中心頻點(diǎn)=某個值,要求這個值小于
25PPm就滿足要求
五、 TX Power測試
1. 測試接線圖Figure3,在串口里面對板子測試模式進(jìn)行如下設(shè)置:
a) Standard Module--- b) TX Power Test (Modulated)--- a) Output Continuous
2. 頻譜分析儀設(shè)置:
Start freq = 2.4 GHz , Stop freq = 2.5 GHz , Ref amp = 10 dBm , sweep time = 100 ms , RBW = 3 MHz
點(diǎn)擊TRACE進(jìn)入,點(diǎn)擊Trace設(shè)置Max Hold mode
3. 在串口里面先將channel切換到11,然后按+鍵一直切換到channel26,讀取測試結(jié)果,
點(diǎn)點(diǎn)擊MKR按鍵,然后點(diǎn)擊MKR→鍵,點(diǎn)擊peak點(diǎn)和next peak點(diǎn)讀取功率
4. 測試截圖

5. 測試標(biāo)準(zhǔn):
要求功率大于2dBm
六、TX spurious
1. 測試接線圖Figure3,在串口里面對板子測試模式進(jìn)行如下設(shè)置:
a) Standard Module---a) TX Power Test (CW)---- a) Output Continuous 2. 點(diǎn)擊FREQ按鈕,然后點(diǎn)擊start,輸入1GHz ,然后點(diǎn)擊stop按鈕輸入30GHz 3. 測試結(jié)果如下圖所示:

6. H2點(diǎn)測試:
測試接線圖Figure3,在串口里面對板子測試模式進(jìn)行如下設(shè)置:
a) Standard Module---a) TX Power Test (CW)---- a) Output Continuous
點(diǎn)擊FREQ按鈕,然后點(diǎn)擊start,輸入4.8GHz ,然后點(diǎn)擊stop按鈕輸入5.0GHz,測試結(jié)果如下圖: